PCB License

IQCS will guide companies to get PCB License on PAN India Basis.

The Central Pollution Control Board (CPCB), statutory organisation, was constituted in September, 1974 under the Water (Prevention and Control of Pollution) Act, 1974. Further, CPCB was entrusted with the powers and functions under the Air (Prevention and Control of Pollution) Act, 1981.
It serves as (i) to promote cleanliness of streams and wells in different areas of the States by prevention, control and abatement of water pollution, and (ii) to improve the quality of air and to prevent, control or abate air pollution in the country.

Standards  for PCB

  • Air Quality Standard
  • Water Quality Standard
  • Vehicular Standard
  • Noise Standard/Rules
  • Bio medical incinerator
  • Auto fuel quality
  • Common HW incinerator
  • Generator set
  • Industry specific standard

Air Quality Standard

Sl No:

Pollutant

Time weighted Average

concentration in ambient air

 

Industrial residential Rural and other area

Ecologically sensitive area notified by central government

(1)

(2)

(3)

(4)

(5)

1

so2 µg/m3

24 hrs

80

80

2

no2 µg/m3

24 hrs

80

80

3

particulate matter size less than 10µm µg/m3

24 hrs

100

100

 

particulate matter size less than 2.5µm µg/m3

24 hrs

60

60

4

ozone µg/m3

1 hr

180

180

5

lead µg/m3

24 hr

1

1

6

co  mg/m3

1 hr

04

04

7

NH3 µg/m3

24 hr

400

400

8

Benzene µg/m3

Annual

05

05

9

BAP µg/m3

Annual

01

01

10

Arsenic µg/m3

Annual

06

06

11

Nickel µg/m3

Annual

20

20

 

Water quality Standard

Designated-Best-Use

Class of water

Criteria

Drinking WaterSource without conventional treatment but after disinfection

A

  • Total Coliforms Organism MPN/100ml shall be 50 or less
  • pH between 6.5 and 8.5
  • Dissolved Oxygen 6mg/l or more
  • Biochemical Oxygen Demand 5 days 20C 2mg/l or less

Outdoor bathing (Organised)

B

  • Total Coliforms Organism MPN/100ml shall be 500 or less pH between 6.5 and 8.5 Dissolved Oxygen 5mg/l or more
  • Biochemical Oxygen Demand 5 days 20C 3mg/l or less

Drinking water source after conventional treatment and disinfection

C

  • Total Coliforms Organism MPN/100ml shall be 5000 or less pH between 6 to 9 Dissolved Oxygen 4mg/l or more
  • Biochemical Oxygen Demand 5 days 20C 3mg/l or less

Propagation of Wild life and Fisheries

D

  • pH between 6.5 to 8.5 Dissolved Oxygen 4mg/l or more
  • Free Ammonia (as N) 1.2 mg/l or less

Irrigation, Industrial Cooling, Controlled Waste disposal

E

  • pH between 6.0 to 8.5
  • Electrical Conductivity at 25C micro mhos/cm Max.2250
  • Sodium absorption Ratio Max. 26
  • Boron Max. 2mg/l

Below-E

Not Meeting A, B, C, D & E Criteria

Industry effluent standard

 

Sl No:

 

Parameter

                                  Standards

Inland surface water

Public Sewers

Land for irrigation

Marine coastal area

1

Suspended solids mg/l, Max.

100

 600

 200

a)For process waste water100 (b) For cooling water effluent 10 percent above total suspended matter of influent

2

Particulate size of suspended solids

Shall pass 850 micron IS Sieve

 

 

(a)Floatable solids ,max. 3mm. (b)Settleable solids, max. 850 microns. 2 4

3

 

Temperature

shall not exceed 5oC above the receiving water temperature

---

 

---

shall not exceed 5 o C above the receiving water temperature

4

Oiland grease mg/l Max

10

20

10

20

5

Total residual chlorine mg/l Max

1.0

 

 

1.0

6

Biochemical Oxygen demand 1 [3 days at 27 oC] mg/l

30

350

100

100

Lets discuss